mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Timing Cover|Specifications|Page 3447 > < Timing Cover|Specifications|Page 3445
Page 11
background image

-

Tighten the engine front cover studs to 7 Nm (62 inch lbs.).

-

Using a new gasket, install the coolant pump.

-

Tighten the fasteners in the sequence shown.
-

Tighten bolt No. 12 to 10 Nm (89 inch lbs.).

-

Tighten all other fasteners to 28 Nm (21 ft. lbs.).

5. Install the two oil pan bolts and tighten to 10 Nm (89 inch lbs.).

6. Install the catalyst monitor sensor electrical connector bracket.

7. Connect the catalyst monitor sensor electrical connector.

Item 9: Crankshaft Front Seal Installation Note

1. Clean and inspect the mating surface.

2. NOTE:  Lubricate the crankshaft front seal lips with clean engine oil prior to installation.

Assemble the special tools, then place the crankshaft front seal onto the special tools.

Timing Cover|Specifications|Page 3447 > < Timing Cover|Specifications|Page 3445