mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 9404 > < Initial Inspection and Diagnostic Overview|Page 9402
Page 7
background image

Test O7-O8

Normal Operation

The SJB monitors the headlamp switch position. When the headlamp switch is in the parking lamps ON position, the SJB supplies voltage to the
parking and license lamps. If a problem is detected with any of the signal circuits to the headlamp switch, the SJB will default the parking lamps and
the headlamps ON. The LH front parking/turn lamp and side marker are supplied voltage from circuit 1340 (DG). The RH front parking/turn lamp and
side marker are supplied voltage from circuit 1339 BK/PK). The LH auxiliary parking lamp is supplied voltage from circuit 1344 (VT/LB). The RH
signal mirror is supplied voltage from circuit 1343 (PK/OG). The LH rear lamp is supplied voltage from circuit 1364 (DB/YE). The RH rear turn
lamp is supplied voltage from circuit 1366 TN/RD). The license lamps are supplied voltage from circuit 1370 (DG/LG). Ground for the LH front and
side lamps is supplied through circuit 1205 (BK) from the BEC. Ground for the rear lamps is supplied through circuit 1205 (BK).

Possible Causes

-

circuit 1205 (BK) open

-

circuit 1339 (BK/PK) open

-

circuit 1340 (DG) open

-

circuit 1343 (PK/OG) open

-

circuit 1344 (VT/LB) open

-

circuit 1364 (DB/YE) open

-

circuit 1366 (TN/RD) open

-

circuit 1370 (DG/LG) open

Initial Inspection and Diagnostic Overview|Page 9404 > < Initial Inspection and Diagnostic Overview|Page 9402