mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Relays and Modules - HVAC > < A/C Pressure Cutoff Switch
Page 1
background image

Refrigerant Pressure Sensor / Switch: Description and Operation
A/C Pressure Switch

A/C Cycling Switch

The A/C cycling switch is mounted on a Schrader valve-type fitting on the top of the suction accumulator/drier.

-

A valve depressor, located inside the threaded end of the A/C cycling switch, presses in on the Schrader valve stem.

-

This allows the suction pressure inside the suction accumulator/drier to control the operation of the A/C cycling switch.

-

The electrical switch contacts open when the suction pressure drops to 152-193 kPa (22-28 psi).

he contacts close when the suction pressure rises to 276-324 kPa (40-47 psi).

-

When the A/C cycling switch contacts close, the signal to energize the A/C clutch is sent to the wide open throttle A/C cutoff relay.

-

When the A/C cycling switch contacts open, the A/C clutch field coil is deenergized and compressor operation stops.

-

The A/C cycling switch will control the A/C evaporator core pressure at a point where the plate/fin surface temperature will be maintained slightly
above freezing.

-

This prevents icing of the A/C evaporator core and blockage of airflow.

-

It is not necessary to discharge the refrigerant system to remove the A/C cycling switch.