mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Interior Lighting Relay > < Horn Relay|Locations|Page 12001
Page 1
background image

Horn Relay: Testing and Inspection

Terminals

1. Use 73 Digital Multimeter to check for continuity between terminal 2 and all other terminals. If resistance is 5 ohms or less between terminal 2

and any other terminal, replace the relay. If resistance is greater than 5 ohms, continue the test. Use two jumper wires to connect relay terminal 1
and terminal 3 directly to the positive battery terminal. Set 73 Digital Multimeter in the volts position and check for voltage at terminal 4. If
battery voltage is not indicated, replace the relay. If battery voltage is indicated, connect a third jumper wire to terminal 2 and ground the jumper
wire to a known good ground. Check for voltage at terminal 5. If battery voltage is not indicated, replace the relay.

Interior Lighting Relay > < Horn Relay|Locations|Page 12001