Air Bag Control Module: Service and Repair

REMOVAL

WARNING:  TO AVOID ACCIDENTAL DEPLOYMENT AND POSSIBLE PERSONAL INJURY, THE BACKUP POWER SUPPLY MUST
BE DEPLETED BEFORE REPAIRING OR REPLACING ANY AIR BAG SUPPLEMENTAL RESTRAINT SYSTEM (SRS)
COMPONENTS. TO DEPLETE THE BACKUP POWER SUPPLY ENERGY, DISCONNECT THE BATTERY GROUND CABLE AND
WAIT ONE MINUTE. BE SURE TO DISCONNECT AUXILIARY BATTERIES AND POWER SUPPLIES (IF SO EQUIPPED).
 

CAUTION:  Electronic modules are sensitive to static electrical charges. If exposed to these charges, damage can result.

NOTE:  The safing sensor is internal to the air bag diagnostic monitor and is not replaced separately.

1. Disconnect the battery ground cable.
2. Remove the RH cowl side trim panel.

3. Remove the air bag diagnostic monitor.

1

Disconnect the two electrical connectors.

2

Remove the screws.

3

Remove the air bag diagnostic monitor bracket.

4

Remove the air bag diagnostic monitor.

INSTALLATION 

Follow the removal procedure in reverse order.