2. Attach Dial Indicator With Bracketry to End Play Checking Tool.

-

Position the dial indicator bottom on the converter pump drive hub and zero the dial.

3. Lift up on End Play Checking Tool and note the dial indicator reading.

-

If the reading exceeds end play limits, replace the torque converter.

4. Remove the Dial Indicator Tool.

Leakage Checks

1. Clean the outside surface of the torque converter.

2. Install Torque Converter Leak Check Tool and Gasket into convert hub.

3. WARNING:  ALWAYS FOLLOW PROPER SAFETY PROCEDURES WHILE USING PRESS. 