Page 2
background image

Air Conditioning High Pressure Switch

Typical Air Conditioning Pressure Sensor

The A/C pressure cut-off switch is used to interrupt A/C compressor operation in the event of high system discharge pressures.

-

The A/C pressure cut-off switch is mounted on a Schrader valve-type fitting on the high pressure side of the A/C manifold and tube.

-

A valve depressor, located inside the threaded end of the A/C pressure cut-off switch, presses on the Schrader valve stem.

-

This allows the A/C pressure cut-off switch to monitor the compressor discharge pressure.

-

When the compressor discharge pressure rises to approximately 2,896 kPa (420 psi), the switch contacts open, disengaging the A/C compressor.

-

When the pressure drops to approximately 1,724 kPa (250 psi), the contacts close to allow operation of the A/C compressor.

-

It is not necessary to discharge the refrigerant system to remove the A/C pressure cut-off switch.