Mountaineer 2WD V6-245 4.0L VIN X SFI (2000)
Voltage Regulator: Service and Repair
REMOVAL
1. Remove the generator. For additional information, refer to Generator Service and Repair.
2. Remove the voltage regulator/brush holder assembly.
1
Remove the screws.
2
Remove the voltage regulator/brush holder assembly.
INSTALLATION
1. Install the voltage regulator/brush holder assembly.
1
Depress the brushes and insert a wire to hold brushes during installation.
2
Install the voltage regulator/brush holder assembly.
3
Install the screws and remove the wire.
2. Install the generator. For additional information, refer to Generator Service and Repair.