AA10-AA11

Normal Operation

The trailer battery charge relay coil receives voltage from the smart junction box (SJB) fuse 12 (5A) through circuit CBP12 (GN/WH) when the
ignition switch is in the RUN or ACC position. Ground for the trailer battery charge relay coil is supplied through circuit GD120 (BK/GN). The
battery junction box (BJB) fuse 13 (30A) supplies voltage to the trailer battery charge relay through circuit SSB13 (GY/RD). When the trailer battery
charge relay is energized, the voltage is routed to the trailer tow connector through circuit CAT14 (OG).

Possible Causes

-

Fuse

-

Circuit CAT14 (OG) open or short to voltage

-

Circuit CBP12 (GN/WH) open or short to voltage

-

Circuit GD120 (BK/GN) open

-

Circuit SSB13 (GY/RD) open

-

Trailer battery charge relay

-

Trailer

-

SJB

Tests AB: The Trailer Electric Brakes Are Inoperative/Do Not Operate Correctly

PINPOINT TEST AB: THE TRAILER ELECTRIC BRAKES ARE INOPERATIVE/DO NOT OPERATE CORRECTLY