4. Disconnect the A/C pressure transducer electrical connector.
5. Remove the condenser inlet fitting nut and disconnect the fitting.

-

Discard the O-ring seal.

-

To install, tighten to 8 Nm (71 lb-in).

6. Remove the condenser outlet fitting nut and disconnect the fitting.

-

Discard the O-ring seal.

-

To install, tighten to 8 Nm (71 lb-in).

7. Detach the 2 compressor-to-condenser discharge line clips.
8. Remove the 2 cooling module bolts and position the cooling module rearward.

-

To install, tighten to 12 Nm (9 lb-ft).

9. Remove the upper radiator air deflector.

10. Remove the 2 condenser core bolts.

-

To install, tighten to 12 Nm (9 lb-ft).

11. Remove the condenser core.
12. Remove the 2 condenser air deflectors.
13. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

14. Evacuate, leak test and charge the refrigerant system. 