1. Install a new gasket onto the VCT housing.

RH VCT housing

2. Position the RH VCT housing and install the 2 bolts.

-

Tighten to 10 Nm (89 lb-in).

LH VCT housing

3. Position the LH VCT housing and install the 2 bolts.

-

Tighten to 10 Nm (89 lb-in).

All VCT housings

4. Install the timing drive components. For additional information, refer to Timing Drive Components  See: Service and Repair/Removal and

Replacement.