Accumulator HVAC: Service and Repair

REMOVAL

1. Disconnect the battery ground cable.
2. Recover the refrigerant.

3. Disconnect the A/C cycling switch electrical connector.

4. Disconnect the suction accumulator/drier to A/C evaporator core fitting.

CAUTION:  Use a back-up wrench to prevent damage to the tubes.

5. Disconnect the A/C manifold and tube spring lock coupling from the suction accumulator/drier.

6. Remove the suction accumulator/drier.

1

Remove the screw from the mounting bracket.

2

Lift the suction accumulator/drier out.