Mountaineer 4WD V6-4.0L VIN E (1999)
Hose/Line HVAC: Description and Operation
NOTE: Installation of a new suction accumulator/drier is not required when repairing the air conditioning system except when there is physical
evidence of system contamination from a failed A/C compressor or damage to the suction accumulator/drier.
The condenser to evaporator tube contains high pressure liquid refrigerant upstream of the A/C evaporator core orifice.
The A/C manifold and tube is attached to the A/C compressor with O-ring seals and has the following features:
^
The upstream side contains low pressure refrigerant gas.
^
The downstream side contains high pressure refrigerant gas and a fitting used to mount a serviceable high-pressure A/C charge port valve.
The downstream side also contains a fitting used to mount the A/C pressure cut-off switch. A long-travel Schrader-type valve stem core is installed in the
fitting so that the A/C pressure cut-off switch can be removed without discharging the A/C system.