Turn Signal Switch: Initial Inspection and Diagnostic Overview

1. Verify the customer concern by operating the multi-function switch or ignition switch. 
2. Visually inspect for the obvious signs of mechanical and electrical damage: 

Mechanical 
^

Damaged multi-function switch  

^

Damaged ignition switch  

Electrical 
^

Failed fuse(s)

^

Damaged wiring harness

^

Loose or corroded connections

3. If the concern remains after the inspection, connect the New Generation STAR (NGS) Tester to the Data Link Connector (DLC) located beneath

the instrument panel and select the vehicle to be tested from the NGS menu. If the NGS does not communicate with the vehicle:
^

check that the program card is properly installed.

^

check the connections to the vehicle.

^

check the ignition switch position.

4. If the NGS still does not communicate with the vehicle, refer to the New Generation STAR Tester manual.
5. Perform the DATA LINK DIAGNOSTIC TEST. If the NGS responds with:

^

CKT914, CKT915 or CK170 - ALL ECUS NO RESP/NOT EQUIP, diagnose the Module Communications Network.

^

NO RESP/NOT EQUIP for GEM/CTM, go to Pinpoint Test E.See: Pinpoint Tests/Test E

^

SYSTEM PASSED, retrieve and record the continuous diagnostic trouble codes (DTCs), erase the continuous DTCs and perform self-test
diagnostics for the GEM/CTM.

6. If the DTCs retrieved are related to the concern, go to the GEM/CTM Diagnostic Trouble Code (DTC) Index to continue diagnostics.See:

Diagnostic Trouble Code Descriptions/GEM/CTM Diagnostic Trouble Code (DTC) Index

7. If no DTCs related to the concern are retrieved, proceed to Symptom Chart to continue diagnostics.See: Symptom Related Diagnostic Procedures