Refrigerant: Description and Operation

REFRIGERANT SYSTEM DYE

Fluorescent refrigerant system dye is added to the refrigerant system at the factory to assist in refrigerant system leak diagnosis using a Rotunda
approved ultraviolet blacklight. It is not necessary to add additional dye to the refrigerant system before diagnosing leaks, even if a significant amount
of refrigerant has been removed from the system. Replacement suction accumulators are shipped with a fluorescent dye "wafer" included in the
desiccant bag which will dissolve after approximately 30 minutes of continued A/C operation. It is not necessary to add dye after flushing or filtering
the refrigerant system because a new suction accumulator is installed as part of the flushing or filtering procedure. Additional refrigerant system dye
should only be added if more than 50% of the refrigerant system lubricant capacity has been lost due to a fitting separation, hose rupture or other
damage.