Refrigerant: Testing and Inspection
Electronic Leak Detection

ELECTRONIC LEAK DETECTION

Refrigerent Leak Detector

SPECIAL TOOL(S)

CAUTION:  Good ventilation is necessary in the area where electronic A/C leak testing is to be carried out. If the surrounding air is
contaminated with refrigerant gas, the leak detector will indicate this gas all the time. Odors from other chemicals such as antifreeze, diesel
fuel, disc brake cleaner, or other cleaning solvents can cause the same problem. A fan, even in a well-ventilated area, is very helpful in removing
small traces of contamination from the air that might affect the leak detector.

1. NOTE:  The system pressure should be between 413-551 kPa (60-80 psi) at 24°C (75°F) with the engine off.

Leak test the refrigerant system using the Refrigerant Leak Detector. Follow the instructions included with the leak detector for handling and
operation techniques.

2. If a leak is found, discharge and recover the refrigerant.

-

Repair the system.

-

Test the system for normal operation.