background image

4. For the A/C condenser core, add 30 ml (1 ounce) of clean PAG Refrigerant Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft

YN-12-C) or equivalent meeting Ford specification WSH-M1C231-B to the A/C condenser core or the suction accumulator/drier inlet tube.

5. Add 60 ml (2 ounces) of clean PAG Refrigerant Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft YN-12-C) or equivalent

meeting Ford specification WSH-M1C231-B to the suction accumulator/drier inlet tube when carrying out each of the following repairs:
-

installation of a new A/C evaporator core orifice

-

installation of a new A/C compressor pressure relief valve

-

Installation of a new refrigerant line

-

repair of an O-ring seal leak

-

repair of a charge port leak

6. Installation of new components that do not require discharge of refrigerant and resulting oil loss, such as the A/C cycling switch and the A/C

pressure transducer, do not require additional oil.

Refrigerant Pressure Sensor / Switch, HVAC > < Refrigerant Oil|Capacity Specifications|Page 7893