mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Solar Sensor, HVAC > < High Pressure Sensor / Switch, HVAC|Locations|Page 1726
Page 1
background image

High Pressure Sensor / Switch: Description and Operation

HIGH PRESSURE CUTOFF SWITCH

The high pressure cutoff switch is used to interrupt A/C compressor operation in the event of high system discharge pressures.
-

The high pressure cutoff switch is mounted on a Schrader valve-type fitting on the high pressure side of the compressor manifold and tube
assembly.

-

A valve depressor, located inside the threaded end of the high pressure cutoff switch, presses on the Schrader valve stem.

-

This allows the high pressure cutoff switch to monitor the A/C compressor discharge pressure.

-

When the A/C compressor discharge pressure rises, the switch contacts open, disengaging the A/C compressor. When the pressure drops, the
contacts close to allow operation of the A/C compressor.

-

It is not necessary to discharge the refrigerant system to remove the high pressure cutoff switch.

Solar Sensor, HVAC > < High Pressure Sensor / Switch, HVAC|Locations|Page 1726