10. Attach the restraint system diagnostic tools to the clockspring electrical connectors at the top of the steering column.

11. Push in on the glove compartment sides, releasing the stops and lowering it out of the way.

12. Through the glove compartment opening, release the tab and disconnect the passenger air bag module electrical connector.

13. Attach the restraint system diagnostic tool to the vehicle harness side of the passenger air bag module electrical connector.

Vehicles without safety canopies

14. CAUTION:  Do not deactivate the safety canopy module circuit by removing the safety canopy bridge resistor from the safety canopy

electrical connector.

If the safety canopy bridge resistor is removed, an open circuit fault will be generated by the restraints control module (RCM).