mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Expansion Block/Orifice Tube|Description and Operation|Page 5652 > < Expansion Block/Orifice Tube|Description and Operation|Page 5650
Page 1
background image

Expansion Block/Orifice Tube: Service and Repair

Thermostatic Expansion Valve

Removal and Installation

NOTE:  An in-line filter is installed in the auxiliary evaporator inlet line at the floorpan bracket connection. A restriction in this filter may cause
misdiagnosis of a failed Thermostatic Expansion Valve (TXV). This filter must be inspected before a new TXV is installed.

1. Recover the refrigerant.

2. Remove the D-pillar trim panel.

3. Detach the rear portion of the LH quarter trim panel and position away from the TXV.

4. Remove the 4 clips and the TXV cover.

5. Remove the insulating tape.

-

Retain the tape for reuse.

6. Remove the temperature sensing bulb clip and detach the temperature sensing bulb from the evaporator outlet line.

7. Disconnect the 2 TXV fittings and remove the TXV.

-

Discard the O-ring seals.