Discard the O-ring seal.

7. Remove the condenser-to-evaporator line bracket nut.

-

To install, tighten to 7 Nm (62 lb-in).

8. Remove the condenser outlet fitting nut and disconnect the fitting.

-

Discard the O-ring seal.

-

To install, tighten to 8 Nm (71 lb-in).

9. Disconnect the auxiliary evaporator inlet line fitting (if equipped).

-

Discard the O-ring seals.

10. Remove the front portion of the condenser-to-evaporator line.

11. Remove the A/C line bracket nut at the dash panel and detach the bracket.

-

To install, tighten to 6 Nm (53 lb-in).

12. Disconnect the evaporator inlet fitting.

-

Discard the O-ring seals.

13. Remove the rear portion of the condenser-to-evaporator line.

14. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

15. Evacuate, leak test and charge the refrigerant system.