mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Compressor To Condenser Discharge Line|Page 1394 > < Compressor To Condenser Discharge Line|Page 1392
Page 2
background image

8. Remove the condenser inlet fitting nut and disconnect the fitting.

-

Discard the O-ring seal.

-

To install, tighten to 8 Nm (71 lb-in).

9. NOTE: The LH clip should be disconnected from the line. The RH clip should be disconnected from the cooling module.

Detach the 2 compressor-to-condenser discharge line clips at the cooling module.

10. Remove the compressor-to-condenser discharge line.

11. To install, reverse the removal procedure.

-

Install a new gasket seal and O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

12. Evacuate, leak test and charge the refrigerant system.

Condenser To Evaporator Line

Condenser to Evaporator Line

Removal and Installation

Compressor To Condenser Discharge Line|Page 1394 > < Compressor To Condenser Discharge Line|Page 1392