mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2774 > < Initial Inspection and Diagnostic Overview|Page 2772
Page 3
background image

No

REPAIR the circuit in question. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
A5 CHECK FOR CORRECT PCM OPERATION

-

Disconnect all the PCM connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the PCM connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new PCM. REFER to Computers and Control Systems. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the
network test with the scan tool.

-------------------------------------------------

Pinpoint Test B: The Transmission Control Module (TCM) Does Not Respond To The Scan Tool

Communications Network

Pinpoint Tests

Pinpoint Test B: The Transmission Control Module (TCM) Does Not Respond To The Scan Tool

Refer to Wiring Diagram Set 14, Module Communications Network for schematic and connector information.  See: Diagrams/Electrical
Diagrams/Diagrams By Number

Refer to Wiring Diagram Set 30, Transmission Controls - 6R60 for schematic and connector information.  See: Diagrams/Electrical Diagrams/Diagrams
By Number

Normal Operation

The 6R60 transmission utilizes a Transmission Control Module (TCM) to control transmission functions. The TCM communicates with the scan tool
through the High Speed Controller Area Network (HS-CAN).

This pinpoint test is intended to diagnose the following:

-

Fuse

-

Wiring, terminals or connectors

-

TCM

PINPOINT TEST B: THE TCM DOES NOT RESPOND TO THE SCAN TOOL

NOTICE:  Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

NOTE:  Failure to disconnect the battery when instructed will result in false resistance readings. Refer to Battery.

-------------------------------------------------
B1 CHECK THE TCM VOLTAGE SUPPLY CIRCUITS FOR AN OPEN

-

Ignition OFF.

-

Disconnect: TCM C1575 (6R60 Transmission).

Initial Inspection and Diagnostic Overview|Page 2774 > < Initial Inspection and Diagnostic Overview|Page 2772