Page 7
background image

9. Pull the release tab and pull down on the transmission bulkhead electrical connector retainer.

10. NOTICE: Do not touch the electrical connector pins or the exposed solenoid tabs on the transmission bulkhead electrical connector.

Electrostatic discharge may occur and may cause damage to the mechatronic unit.

With the release tab down, pull the outer shell of the transmission bulkhead electrical connector out of the mechatronic assembly.

11. NOTICE: Do not touch the electrical connector pins or the exposed solenoid tabs on the mechatronic unit. Electrostatic discharge may

occur and may cause damage to the mechatronic unit.

Pull the transmission bulkhead electrical connector out of the transmission.

12. NOTICE: During removal of the mechatronic assembly, the thermal bypass valve will fall out of the transmission case. Damage to the

valve will occur if the valve falls out.

Remove the 11 bolts from the mechatronic assembly and remove the mechatronic assembly and the bypass valve.

Seals and Gaskets, A/T|5R55S|Page 3759 > < Seals and Gaskets, A/T|5R55S|Page 3757