1. Lubricate the O-ring seals with clean PAG oil.

2. Position the evaporator core orifice tube in the special tool.

3. Using the special tool, install the evaporator core orifice tube into the condenser to evaporator line.

4. Align the index marks and connect the two halves of the condenser to evaporator line.
5. Install the condenser to evaporator line.