mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Temperature Blend Door Actuator - RH, EATC|Page 9152 > < Temperature Blend Door Actuator - RH, EATC|Page 9150
Page 3
background image

VACUUM CONTROL MOTOR - FLOOR DOOR

Removal and Installation

1. Remove the instrument panel. Refer to:  Body and Frame, Interior Moulding/Trim, Dashboard/Instrument Panel, Service and Repair, Instrument

Panel, See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and Repair/Instrument Panel

2. Remove the shield screw.
3. Remove the shield.
4. Disconnect the floor door vacuum control motor vacuum connector.
5. Remove the 2 floor door vacuum control motor screws.

6. Rotate the floor door vacuum control motor until it clears the retaining arm and remove the vacuum control motor.
7. To install, reverse the removal procedure.

Temperature Blend Door Actuator - RH, EATC|Page 9152 > < Temperature Blend Door Actuator - RH, EATC|Page 9150