mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Air Door Vacuum Solenoid Valve, HVAC > < Temperature Blend Door Actuator - LH|Page 7196
Page 9
background image

-

To install, tighten to 6 Nm (53 lb-in).

5. Remove auxiliary heater core and evaporator core housing nut.

-

To install, tighten to 6 Nm (53 lb-in).

6. Disconnect the auxiliary harness electrical connector.
7. Disconnect the auxiliary temperature blend door actuator electrical connector.
8. Remove the 3 auxiliary temperature blend door actuator screws.
9. Remove the auxiliary temperature blend door actuator.

10. To install, reverse the removal procedure.

Vacuum Control Motor - Air Inlet Door

VACUUM CONTROL MOTOR - AIR INLET DOOR

Removal and Installation

1. Lower the glove compartment.
2. Remove the screws and the heater core and evaporator core housing support brace.

3. Disconnect the air inlet door vacuum control motor vacuum connector.
4. Remove the 2 air inlet door vacuum control motor screws.
5. Rotate the air inlet door vacuum control motor until it clears the retaining arm and remove the vacuum control motor.
6. To install, reverse the removal procedure.

Air Door Vacuum Solenoid Valve, HVAC > < Temperature Blend Door Actuator - LH|Page 7196