Page 2
background image

4. Pull the spring lock coupling fitting apart.

5. Remove the O-ring seals with a non-metallic tool.

CAUTION:  Do not use metal O-ring tools. They can cause axial scratches across the O-ring grooves resulting in refrigerant leaks.

6. Remove the lock coupling spring with a small hooked wire, if damaged.

CAUTI0N:  Do not use a screwdriver or similar tool to remove the A/C tube lock coupling spring. They can cause axial scratches across the
O-ring grooves resulting in refrigerant leaks.

7. Install the A/C tube lock coupling spring.