Accumulator HVAC: Description and Operation

NOTE:  Replacement of the suction accumulator/drier is necessary any time a major component of the refrigerant system is replaced. Major components
include the following:

-

A/C condenser core

-

A/C compressor 

-

A/C evaporator core 

-

a refrigerant hose/line

An A/C evaporator core orifice or O-ring seal is not considered a major component but the A/C evaporator core orifice should be replaced whenever the
A/C compressor is replaced for lack of performance.

The suction accumulator/drier is mounted on the A/C accumulator bracket and positioned to the right of the radiator. The inlet tube of the suction
accumulator/drier is attached to the A/C evaporator core. The outlet tube attaches to the A/C manifold and tube.

After entering the inlet of the suction accumulator/drier, heavier oil-laden refrigerant contacts an internally mounted dome (which serves as an umbrella)
and drips down onto the bottom of the canister.

-

A small diameter oil bleed hole in the bottom of the vapor return tube allows the accumulated heavier liquid refrigerant and oil mixture to re-enter
the compressor suction line at a controlled rate.

-

As this heavier mixture passes through the small diameter liquid bleed hole, it has a second chance to vaporize and recirculate through the A/C
compressor without causing compressor damage due to slugging.

-

A fine-mesh screened filter fits tightly around the bottom of the vapor return tube to filter out refrigerant system contaminant particles.

-

A desiccant bag is mounted inside the canister to absorb any moisture which may be in the refrigerant system.