Sable V6-183 3.0L VIN U FI (1998)
Refrigerant Pressure Sensor / Switch: Description and Operation
A/C Pressure Switch
The A/C cycling switch is mounted on a Schrader valve fitting on the top of the suction accumulator/drier.
-
A valve depressor, located inside the threaded end of the A/C cycling switch, presses in on the Schrader valve stem.
-
This allows the suction pressure inside the suction accumulator/drier to control the operation of the A/C cycling switch.
-
The electrical switch contacts will open when the suction pressure drops to 152-193 kPa (22-28 psi).
-
The contacts will close when the suction pressure increases to 276-324 kPa (40-47 psi).
-
Ambient temperature below approximately 7-10°C (45-50°F), during cold weather seasons, prevents the A/C cycling switch contacts from closing.
This is due to the pressure/temperature relationship of the refrigerant and the requirement of the system pressure to reach 276-324 kPa (40-47 psi)
to close the A/C cycling switch contacts.
-
When the A/C cycling switch contacts close, the signal to energize the A/C clutch is sent to the powertrain control module.
-
The powertrain control module then supplies the voltage to energize the A/C clutch for A/C compressor operation.
-
When the A/C cycling switch contacts open, the powertrain control module opens the A/C clutch electrical circuit to de-energize the A/C clutch.
A/C compressor operation stops.
-
The A/C cycling switch, when functioning properly, will control the A/C evaporator core pressure at a point where the plate/fin surface
temperature will be maintained slightly above freezing.
-
This prevents A/C evaporator core icing and the blockage of airflow.