Page 4
background image

Figure 2

7.

For Spade Terminals - Measure from fuel pump electrical connectors toward the mounting flange and cut two (2) two inch jumper wires from the
pump wires, Figure 2.

a.

Install a 1" (25.4 mm) piece of heat shrink tubing over each end of wire.

b.

Install the small female spade terminal onto the red wire end and the large female spade terminal onto the black wire end.

c.

Crimp and solder new terminals onto the wires.

d.

Put shrink tubing over the new crimp and solder connection.