mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Key Reminder Switch > < Instrument Panel Voltage Regulator|Description and Operation
Page 1
background image

Instrument Panel Voltage Regulator: Testing and Inspection

1.

Disconnect wiring harness connector at sending unit. Connect a test lamp or voltmeter between terminal in wiring harness connector and ground.

2.

With ignition switch in ON position, light should pulse or meter reading should fluctuate.

3.

If lamp lights but does not pulse, or if meter reading remains steady, check ground to IVR. If ground is satisfactory, IVR is defective.

4.

If lamp fails to light, or if meter reads 0 volts, check for open circuit across IVR terminals, indicator gauge terminals, or open circuit in wiring
harness and printed circuit between components.

5.

Connect test lamp or voltmeter ground lead to ground terminal in sending unit wiring harness connector. Light should pulse or meter reading
should fluctuate as in step 2. If not, locate open in ground circuit. Do not apply battery voltage to system or ground output terminals of IVR,
as damage to system components or wiring circuits may result.

Key Reminder Switch > < Instrument Panel Voltage Regulator|Description and Operation