mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Fluorescent Dye Leak Detection|Page 6977 > < Fluorescent Dye Leak Detection|Page 6975
Page 3
background image

1. Verify that the valves on the special tool are closed.

2. Fill the special tool reservoir with 7 ml (0.25 oz) of fluorescent dye.
3. Install the special tool between the high-pressure and low-pressure service gauge port valves.
4. Start the engine.

CAUTION:  Make sure all tools and hoses are clear of the engine cooling fan and drive belt before starting the engine.

5. Open the high-pressure service valve.

6. Open the special tool valves and inject the fluorescent dye into the refrigerant system.

Fluorescent Dye Leak Detection|Page 6977 > < Fluorescent Dye Leak Detection|Page 6975