Low Pressure Sensor / Switch: Description and Operation

The low charge protection switch is used to prevent A/C compressor damage in the event of a low refrigerant charge.

-

The electrical switch contacts open when the suction pressure drops below normal levels. The contacts close when the suction pressure rises.For
information regarding operating pressure(s) specifications, refer to Specifications.

-

When the low charge protection switch contacts open, the A/C clutch field coil is de-energized and compressor operation stops.

-

The low charge protection switch is mounted on a Schrader valve-type fitting on the top of the suction accumulator/drier.

-

A valve depressor, located inside the threaded end of the low charge protection switch, presses in on the Schrader valve stem, allowing the suction
pressure inside the suction accumulator/drier to control the operation of the low charge protection switch.

-

It is not necessary to discharge the refrigerant system to remove the low charge protection switch.