mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Torque Converter|AX4N|Page 5282 > < Torque Converter|AX4N|Page 5280
Page 3
background image

areas to aid in diagnosis. If leaks are present in these areas, replacement of the torque converter IS necessary.

7. Remove air hose, and release air pressure from tool by pulling on release valve ring.

8. Release pressure from the press, and rotate the torque converter so that the tool is facing up. Apply pressure from the press to seal the tool into the

torque converter.

9. Connect air hose to the tool, apply maximum 80 psi.

10. With air pressure applied to the torque converter, inspect for leaks at the seams and impeller hub. A soapy water solution may be used in these

areas to aid in diagnosis. If leaks are present in these areas, replacement of the torque converter is necessary.

Torque Converter|AX4N|Page 5282 > < Torque Converter|AX4N|Page 5280