mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Valve Guide > < Valve Cover|Specifications|Page 2312
Page 2
background image

2.

Remove oil filler cap.

3.

Disconnect PCV hose from PCV valve.

4.

Disconnect throttle linkage cable from rocker arm cover.

5.

Disconnect speed control cable from rocker arm cover, if equipped.

6.

Remove rocker arm cover bolts and cover.

Installation

1.

Clean rocker cover rail on cylinder head and remove all traces of foreign material.

2.

If the "mold in place gasket" is damaged by a cut and/or nick of about 1/8 inch ( maximum of two (2) places), fill in the damaged area with RTV
sealer E8AZ-19562-A and install the rocker arm cover assembly.

CAUTION: Use adequate ventilation when applying sealer.

3.

If the mold-in-place gasket is damaged by cuts longer than 1/8 inch, or by more than three nicks or cuts (any size), replace the entire rocker arm
cover assembly.

4.

If damaged, replace rubber isolator(s) Part No. (E83Z-6C518-A) or washer, bolt and rubber isolator assembly, Part No. (E93Z-6C519-A).

5.

Reinstall rocker cover assembly and tighten all bolts to 8-11.5 Nm (5.9-8.5 lb-ft).

NOTE:Always put one (1) drop of adhesive threadlock (ESE-M2G260-AA) on bolts if they are reused. Only new bolts have pre-applied adhesive.
Failure to do so may result in an oil leak.

6.

Connect PCV hose into rocker arm cover.

7.

Remove aprons.

8.

Start engine and run at fast idle. Check for oil leaks.

NOTE: RTV needs to cure completely before coming in contact with any engine  oil, about one (1) hour cure time at (65-75~F) ambient temperature.

Valve Guide > < Valve Cover|Specifications|Page 2312