mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Main Relay (Computer/Fuel System) > < Diagram Information and Instructions|Page 2109
Page 1
background image

Integrated Control Relay Module: Service and Repair

REMOVAL

1.

Disconnect the negative battery cable.

2.

Locate Integrated Relay Control Module (IRCM) on the left hand strut tower and disconnect electrical harness connector.

3.

Remove the module attaching screws from the bracket and remove the IRCM.

INSTALLATION

1.

Install the IRCM screws and tighten to 24-35 in lb (3-4 Nm).

2.

Connect the electrical harness to the IRCM.

3.

Connect the negative battery cable.

Main Relay (Computer/Fuel System) > < Diagram Information and Instructions|Page 2109