mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Duck Bill Connector|Page 3264 > < Duck Bill Connector|Page 3262
Page 2
background image

Disconnect Tool

5.  Close the tool and push it into the open side of the cage to expand the garter spring and release the female fitting.

6.  After the garter spring is expanded, pull the fittings apart.

7.  Remove the tool from the disconnected coupling.

INSTALL 

1.  Be sure the garter spring is in the cage of the male fitting. If the garter spring is missing, install a new spring by pushing it into the cage opening.

If the garter spring is damaged, remove it from the cage with a small wire hook (do not use a screwdriver) and install a new spring.

Duck Bill Connector|Page 3264 > < Duck Bill Connector|Page 3262