mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Air Door, HVAC > < Wheel Tightening Sequence|Page 5315
Page 1
background image

Accumulator HVAC: Service and Repair

Fig. 2 Spring lock coupling disconnect & connect

1.

Discharge refrigerant from system.

2.

On vehicles with 1.9L/4-114 engines, remove water reservoir.

3.

On all models disconnect electrical connector from clutch cycling pressure switch.

4.

Disconnect suction line from the accumulator/dryer. Refer to Fig. 2.

5.

On vehicles with 1.8L/4-109 engines, loosen mounting strap bolt.

6.

On vehicles with 1.9L/4-114 engines, remove two mounting bolts and mounting strap.

7.

On all models, disconnect suction accumulator/dryer inlet tube from evaporator outlet tube and remove accumulator/dryer.

8.

Reverse procedure to install. Use new O-ring lubricated with refrigerant oil.

9.

Leak test, evacuate and charge system. Check system for proper operation. 