High Pressure Safety Valve HVAC: Service and Repair
A/C High Pressure Safety Valve

REMOVAL

1. Discharge and recover the refrigerant from the A/C system.
2. Remove the A/C compressor pressure relief valve from the A/C compressor manifold.

INSTALLATION

1. Install the A/C compressor pressure relief valve to the A/C compressor manifold. Tighten the A/C compressor pressure relief valve to 6-15 N.m

(51-132 lb-in).

2. Evacuate and charge the A/C system.
3. Leak test the A/C system.