mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Condenser HVAC > < Compressor Fitting HVAC|Specifications|Page 6698
Page 2
background image

INSTALLATION 

1. To install, reverse the removal procedure.

NOTE: 
-

Lubricate the O-ring seals with PAG Compressor Oil (R-134A Systems) F2AZ-19577-AC (MC YN-12) meeting Ford specification
WSH-M1C231-B.

-

Apply Pipe Sealant with Teflon (R) D8AZ-19590-A or equivalent meeting ESB-M1C111-A to the threads of the A/C manifold retaining bolt.

Condenser HVAC > < Compressor Fitting HVAC|Specifications|Page 6698