Blower Motor: Service and Repair

1982-83 FAIRMONT & ZEPHYR & 1982 COUGAR & GRANADA LESS AIR CONDITIONING 

1.

Disconnect battery ground cable.

2.

Remove screw securing right register duct mounting bracket to lower edge of instrument panel.

3.

Remove screws securing ventilator control cable lever assembly to lower edge of instrument panel.

4.

Remove glove box liner.

5.

Remove plastic rivets securing grille to ventilator floor outlet, then the grille from the bottom of the ventilator assembly.

6.

Remove right register duct and register assembly.

7.

Remove screws securing ventilator assembly to blower housing portion of the heater case assembly.

8.

Slide ventilator assembly toward the right, then downward to remove from under instrument panel.

9.

Remove push nut from door crank arm.

10.

Remove control cable housing retaining screw, then control cable assembly from ventilator assembly.

11.

Remove hub clamp spring from blower wheel hub, then slide wheel off shaft.

12.

Remove blower motor attaching screws and the blower motor. Disconnect motor electrical connector before removing from vehicle.

13.

Reverse procedure to install.

Fig. 12 Blower motor. 1982 Cougar XR-7, 1982-83 Fairmont & Zephyr with A/C, 1982-88 Thunderbird, 1983-88 Cougar & 1983-86 LTD & Marquis

1982 COUGAR XR-7, 1982-83 FAIRMONT & ZEPHYR WITH A/C, 1982-88 THUNDERBIRD, 1983-86 LTD & MARQUIS & 1983-88
COUGAR
 

1.

Disconnect battery ground cable.

2.

Remove glove box and disconnect vacuum hose from outside--recirc air door motor.

3.

Remove instrument panel lower right to side attaching bolt.

4.

Remove screw attaching support brace to top of air inlet duct.

5.

Disconnect blower motor lead wire.

6.

Remove nut securing blower motor housing lower bracket to evaporator case.

7.

Remove side cowl trim panel and the blower ground wire screw.

8.

Remove screw securing top of air inlet duct to evaporator case.

9.

Move air inlet duct and blower housing assembly downward from evaporator case, Fig. 12.

10.

Remove blower motor mounting plate screws and the blower motor. Do not remove mounting plate from motor.

11.

Reverse procedure to install.