mini Workshop Repair Guides

Mini Workshop Service and Repair Manuals

Customer Interest: > < Lighting - Bulb Out Message Diagnostics
Page 1
background image

Power Distribution Module: All Technical Service Bulletins
Computer/Control - Coding Failure After FRM Replacement

SI M 61 03 09
General Electrical Systems

October 2009
Technical Service

SUBJECT
Coding Fails After Replacing the FRM

MODEL
R55 (Cooper Clubman, Cooper S Clubman)
R56 (Cooper, Cooper S)
R57 (Cooper and Cooper S Convertible)
Vehicles produced from August 31, 2009 to December 30, 2009

SITUATION

After replacing the FRM3 (Footwell control module), the module fails coding at the first attempt.

CAUSE

Coding data error in ISTA/P 2.35.x.

The coding data file is expected to be corrected with ISTA/P 2.36.0 in December 2009.

CORRECTION

Code the FRM3 a second time. For information on programming and coding with ISTA/P, refer to Centernet / Aftersales Portal / Service / Workshop
Technology / Vehicle Programming.

WARRANTY INFORMATION
Covered under the terms of the MINI New Vehicle Limited Warranty.

Defect Code

61 38 06 00

Labor Operation: Labor Allowance: Description:

Refer to KDS

Refer to KDS

Code FRM3 control module

Customer Interest: > < Lighting - Bulb Out Message Diagnostics