mini Workshop Repair Guides

Mini Workshop Service and Repair Manuals

Removing and Installing / Replacing Convertible Top Tension Bar Bearings|Page 12526 > < Removing and Installing / Replacing Convertible Top Tension Bar Bearings|Page 12524
Page 7
background image

Installation:

1. Ring disk
2. Eccentric bush 
3. Locking pin
4. Screw
Bush must not rest on ring disk (inclination).
Eccentric bush must have contact with roof crossbar through ring disk.
Turn eccentric bush into position and insert locking pin.
Insert screws with Loctite.
Tightening torque 54 34 7AZ See: Service and Repair/Procedures/Opening/Closing Convertible Top In Event of A Technical Fault.

Replacement only:

-

Insert eccentric bush

-

Turn bore to 12 o'clock position

-

Drill new hole for locking pin in roof crossbar (2 mm drill bit)

-

Insert locking pin with Loctite

Installation:

-

Adjust See: Specifications/54 34 Motor-Driven Convertible Top (Electrical Components) Hall sensors

Removing and Installing / Replacing Convertible Top Tension Bar Bearings|Page 12526 > < Removing and Installing / Replacing Convertible Top Tension Bar Bearings|Page 12524