Cooper Convertible (R52) L4-1.6L (W10) (2005)
Screw non-return valve (1) onto special tool so that valve remains closed in injection pipe.
Screw special tool kit 13 5 220 See: Powertrain Management/Fuel Delivery and Air Induction/Tools and Equipment/13 5 220 Adapter onto injection
pipe so that sealing ring is sealed in special tool.
Start engine.
Screw in non-return valve (1) of special tool kit 13 5 220 See: Powertrain Management/Fuel Delivery and Air Induction/Tools and Equipment/13 5 220
Adapter until pressure indication appears in diagnosis system.
Important!
Do not screw in non-return valve up to mechanical stop. This could damage the measuring valve in the injection pipe.