mini Workshop Repair Guides

Mini Workshop Service and Repair Manuals

In-line Plugs, 6- to 50-pin, System Elo|Page 9418 > < In-line Plugs, 6- to 50-pin, System Elo|Page 9416
Page 17
background image

To install contacts, observe cavity numbers on reverse side of socket housing.

Socket Housings, 2x21-, 2x27-pin, Hybrid Systems MQS/MPQ, Elo/Elo-Power

61 13 ... - Socket housings, 2x21-, 2x27-pin, Hybrid Systems MQS/MPQ, Elo/Elo-Power

Manufactured by AMP: The following contact types without strand sealing can be fitted in the socket housings:

-

MQS (Micro Quadlock System)

-

MPQ, width 2.8 mm (Micro Power Quadlock)

-

MPQ, width 5.2 mm (Micro Power Quadlock)

Manufactured by Siemens: The following contact types without strand sealing can be fitted in the socket housings:

-

Elo (electronic contact)

-

Elo-Power 2.8 mm wide (electronic contact for heavy loads)

-

Elo-Power 5.2 mm wide (electronic contact for heavy loads)

Raise lock (1) on housing (2).
Push contact carrier (3) from rear out of housing.

Note:

The second contact carrier is pushed out in the same way.
Pushing out the contact carrier releases the secondary locks of the socket contacts.