Press lock (1) in direction of arrow.
Pull secondary lock (2) in direction of arrow completely out of contact carrier (3).
Press special tool 61 1 135 on inside of contact into contact carrier (2).
Pull wire with socket contact (1) out of contact carrier (2).
In-line Plugs, 24-pin, Hybrid System MQS/MPQ
61 13 ... - In-line plugs, 24-pin, Hybrid System MQS/MPQ
Manufactured by AMP: The following contact types without strand sealing can be fitted in the plug housings:
-
MQS (Micro Quadlock System)
-
MPQ, width 2.8 mm (Micro Power Quadlock)
-
MPQ, width 5.2 mm (Micro Power Quadlock)