Cooper Convertible (R57) L4-1.6L (N12) (2009)
Opening and Closing The Convertible Top
Opening and Closing The Convertible Top
Conditions for opening and closing
Conditions For Opening and Closing
Pump protection counter
A pump protection counter has been implemented to fully safeguard the hydraulic pump. The pump safeguard is active and the function inhibited after an
operation time of 3.5 minutes. A ramp function enables an initial shortened operating period after 1.1 minutes. The full operating time of 3.5 minutes is
available after a waiting period of 15.5 minutes.
When the pump protection is active, a fault is entered in the fault memory.
Overheating protection for drive lock and folding sun roof
The function is inhibited after an operation time of more than 2.20 minutes. The full operating time is available after a waiting period of 50 seconds. It is
always possible to close the convertible top. When the overheating protection is active, a fault is entered in the fault memory.
Convertible top opening duration display
The convertible top opening duration display is on the left beside the rev counter on the steering column. The display is only activated if the convertible
top is opened. Counting only starts when the convertible top is fully opened and only if the engine is running. Two digital counters can be called up in
the computer display. The four-digit counter can be reset using the trip distance reset button. The six-digit counter can only be reset by means of a