Blower with blower output stage
The blower creates the necessary air-mass flow. The blower is fitted after the fresh air recirculated-air flap in the heater/air conditioning system
(pressing blower arrangement). The blower output stage is mounted directly at the housing of the blower motor. The blower output stage is
activated by the IHKA control module with a pulse-width modulated signal (PWM signal). The blower output stage is not diagnosis-capable.

-

Electrical auxiliary heater
The electrical auxiliary heater based on the PTC principle (positive temperature coefficient) is fitted in the heater/air conditioner. The electrical
auxiliary heater directly heats up the air to adjust the temperature of the vehicle interior. The electrical auxiliary heater is only fitted in diesel
engines.

Radiator fan

The radiator fan and the engine cooling are also required for cooling the condenser. The radiator fan is activated by the Digital Engine Electronics
(DME).

A/C compressor

The air-conditioning compressor compresses the refrigerant taken in by the evaporator. The refrigerant is pressed towards the condenser. The
air-conditioning compressor is switched by the compressor coupling. Activation is initiated by the IHKA control module.

Condenser with integrated drier flask

In the condenser, gaseous refrigerant is converted into liquid refrigerant. In the integrated downstream drier flask, any water present in the refrigerant
circuit is bound. The drier insert can be replaced.

Sensors

-

Internal temperature sensor
The internal temperature sensor is built into the IHKA control module. The internal temperature sensor measures the temperature in the control
module. This measured temperature is used by an integrated mathematical model to calculate the value for the interior temperature.
The internal temperature sensor is not force-ventilated. This means that no internal temperature sensor fan is fitted in the IHKA control module.

-

Solar sensor
The solar sensor consists of a photo diode. The solar sensor picks up external light or heat sources (e.g. sunlight). The solar sensor provides the
IHKA control module with an analog signal depending the intensity of the sunlight in each case.
Adaptation to the sunlight is only active in the automatic program. The solar sensor is fitted in the centre of the instrument panel.

-

Sensor for automatic recirculated air control
The AUC sensor is fitted on the micro-filter compartment. The AUC sensor detects the following pollutant emissions:
-

Hydrocarbons (CH)

-

Carbon monoxide (CO)

-

Nitrogen oxides (nitrogen monoxide NO, nitrogen dioxide NO2)

The junction box supplies the AUC sensor with voltage. The junction box electronics evaluate the data of the AUC sensor. This evaluated data is
sent via the K-CAN to the IHKA control module.

-

Evaporator temperature sensor
The evaporator temperature sensor measures the outlet temperature of the air at the evaporator to prevent freezing over. The evaporator
temperature sensor is directly connected to the IHKA control module.

-

Ventilation temperature sensor
The ventilation temperature sensor is integrated in the solar sensor. The ventilation temperature sensor measures the delivery temperature directly
at the upper ventilation air vents.

-

Coolant pressure sensor
The coolant pressure sensor is fitted in the pressure line between the condenser and the evaporator. Depending on the sensor signal, the
air-conditioning compressor is regulated by the IHKA control module in the event of excessive refrigerant pressure. The junction box supplies the
coolant pressure sensor with voltage. The data is evaluated in the junction box electronics. The prepared data is sent across the body CAN
(K-CAN) to the IHKA control module.

Microfilter

A microfilter with activated carbon is built into the IHKA. The activated carbon filter makes an additional contribution to cleaning the fresh air that
enters of gaseous pollutant emissions. There is no detection of the state of the filter.

Notes for Service department

Observe the following information for service:

General information

The following general data is provided for servicing the IHKA:

Seat Heating|Page 8262 > < Seat Heating|Page 8260