Cooper Convertible (R57) L4-1.6L (N12) (2009)
Convertible Top Hydraulic Fluid: Testing and Inspection
54 34 ... - Topping up/extracting fluid, checking fluid level
Note:
No changing of the hydraulic fluid necessary.
-
The hydraulic fluid does not have to be changed because the system is filled with life-time fluid.
-
Only the approved hydraulic fluid may be used in the event of leaks.
-
All hydraulic cylinders must be completely extended.
-
The hydraulic system is automatically bled by repeated actuation.
Necessary preliminary tasks:
-
Remove hydraulic unit See: Body and Frame/Relays and Modules - Body and Frame/Convertible Top Hydraulic Control Unit/Service and Repair
(hydraulic system closed)
Important!
Protect components and work area with suitable materials (e.g. cloths).
Topping up fluid:
Align hydraulic unit vertically.
Open fluid filler plug.
Pour in required amount of fluid from fluid bottle.
Installation:
Check fluid level in the meantime.
Extracting fluid:
Open fluid filler plug.
Tilt hydraulic unit and let fluid flow out or draw off with a suitable auxiliary apparatus.